Product Information
     Features
  • 50 Amp continuous rating with intermittent capability of 400 Amp
  • Intelligent microcontroller operation
  • Full short circuit protection
  • Over current trip with auto reset
  • Automatic switch ON when vehicle voltage is more than 12.8V
  • Automatic switch OFF when vehicle voltage is less than 12.8V
  • No moving parts to wear out
  • No contacts that could burn
  • Turn ON timer automatically adjust turn ON time dependent on battery voltage
  • Dedicated battery monitor output terminals
  • Weatherproof
  • Can be mounted in the engine compartment
  • Integrated load dump protection
  • 1 Year warranty
Technical Notes

Specifications

Input voltage:9VDC to16VDC (12VDC nominal)
Continuous current:50 Amp +/-10%
Voltage drop: 0.15V typically at 20A

: 0.40V maximum at 50A
Short circuit shutdown current:Approximately 400 Amp
Under voltage switch OFF: Ignition <12.8V for >2 seconds
Turn ON delay:5 seconds for Ignition > 13.8V

:60 seconds for Ignition between 12.8V and 13.8V
Over current turn OFF time:10 seconds before auto turn ON again


Operating & Connecting Instructions

Using 16mmsq wire

  • Connect Ground terminal to vehicle chassis.
  • Connect "Main Bat”terminal to positive terminal of the vehicle Battery. Insert a 60A fuse into this line close to the vehicle battery.
  • Connect "Aux Bat” to positive terminal of auxiliary (second) Battery
  • Red LED will blink indicating that the unit has power
  • LED will blink for 5 seconds if Ignition voltage is => 13.8 volt
  • LED will blink for 60 seconds if Ignition voltage is above 12.8 volt and below 13.8 volt
  • LED will flash slow (1 second ON - 1 second OFF) if Ignition voltage is between 6V and 12.8V.
  • The unit will not work if Ignition voltage is below 6 volt
  • Switch turns ON when Red LED turns OFF
  • Red LED turns ON solid for 10 seconds if an overload occurs. During this time the switch is open
  • Overload turn OFF delay is approximately 10 seconds for 60 Amp, 5 seconds for 100 Amp and 1 second for 150 Amp. The switch will automatically turn ON after a 10 second overload turn OFF period

Using 10mmsq wire

  • Connect Ground terminal to vehicle chassis.
  • Remove the link between the "Main Bat” and "Ign” terminal
  • Connect "Main Bat” terminal to positive terminal of the vehicle Battery. Insert a 60A fuse into this line close to the vehicle battery.
  • Run a 1.5mmsq wire from the "Ign" terminal to the 60A fuseat the vehicle battery 
  • Connect "Aux Bat” to positive terminal of auxiliary (second) Battery
  • Red LED will blink indicating that the unit has power
  • LED will blink for 5 seconds if Ignition voltage is => 13.8 volt
  • LED will blink for 60 seconds if Ignition voltage is above 12.8 volt and below 13.8 volt
  • LED will flash slow (1 second ON - 1 second OFF) if Ignition voltage is between 6V and 12.8V.
  • The unit will not work if Ignition voltage is below 6 volt
  • Switch turns ON when Red LED turns OFF
  • Red LED turns ON solid for 10 seconds if an overload occurs. During this time the switch is open
  • Overload turn OFF delay is approximately 10 seconds for 60 Amp, 5 seconds for 100 Amp and 1 second for 150 Amp. The switch will automatically turn ON after a 10 second overload turn OFF period
Battery Monitor Terminals
  • The unit is provided with two battery monitor terminals that can be connected to a battery monitor
  • Terminal M1 is connected to the main battery and terminal M2 is connected to the auxiliary battery
  • KEEP IN MIND THAT M1 & M2 ARE CONNECTED TOGETHER WHEN THE SWITCH IS CLOSED

Warning
Mount in cool place
Do not short Battery leads 
No user serviceable parts inside Return to seller if malfunctioning


Warranty

The product will be replaced or repaired if a failure occurs within one year, from the date of purchase, as a result of faulty materials or workmanship provided that the product is returned to the seller with proof of purchase. Replacement or repair shall be at the discretion of the manufacturer. This warranty excludes failures which results from misuse of the product. The manufacturer and/or seller shall not be liable for personal injury or consequential damages that may result through the use of this product. Lightning damage is excluded from this warranty.


Note: The manufacturer reserves the right to change the product specification without prior notice as a result of his continued development and improvement program.Picture may differ from actual product

 

replica watches replica rolex watches fake watches imitation watches replica rolex fake Rolex